Why does the image suddenly appear off-color?
Please check whether the camera's video parameters, encoding settings, or other related parameters have been modified. If it is unclear which parameters may have been changed, try restoring the factory settings.
After entering the IP address of the Login Camera in the Internet Explorer, the Login interface is not getting connected.
Install the plugin and enable ActiveX control permissions. In the IE toolbar, click "Internet Options" > "Security" > "Custom level" > "Enable all ActiveX controls and plugins".
Can the demo be used to adjust the frequency of the UHF10 Pro to support 928MHz?
Yes, it can support frequency adjustment from 924MHz to 928MHz.
How to adjust the Horizontal and Vertical Position of the CMP200 Rods?
Adjust the position of the magnet above the Hall limit plate so that the indicator light can be used in the vertical and horizontal positions of the pole to light up.
If the Angle of departure from the landing position is too large, you can loosen the two screws at the connecting rod, screw the connecting rod to adjust.
UHF10 Pro device swipes tag unresponsive, the problem still exists after connecting to the demo test.
Please contact our technical team to assist you in resolving this issue.
Why do UHF10E Pro devices have an issue where the distance between the reader and the tag is particularly close (less than 50cm)?
It is not suggest to test the tag distance in the indoor office due to the electronic products will interfere the test distance. Please take an outdoor testing to see if the distance will be normal, otherwise, please contact with our technician for further support.
Why is the real-time monitoring interface not displaying vehicle information correctly?
Ensure that all cameras and channels are correctly configured and linked to the monitoring system. Verify that the real-time data from the cameras is being correctly transmitted and displayed.
Why are vehicles not getting authorized correctly, whether for fixed or temporary access?
Double-check the authorization settings for both fixed and temporary vehicles. Ensure that the correct import/export areas, vehicle types, and license plate numbers are entered accurately. Batch authorization should be used for multiple vehicles.
Why do camera configuration errors occur? Incorrect camera settings may lead to improper vehicle detection and authorization.
Verify that each camera is set according to its designated role (e.g., entrance or exit camera). Ensure that the correct camera device is selected during the setup process.
Why are there errors when connecting LPR series cameras to ZKBio CVSecurity software?
Ensure the correct port is configured (e.g., port 443 for LPRC300, port 80 for LPRC200) and that the device's IP address is correctly assigned. Double-check network settings and cable connections.
Why the parking ticket dispenser can read the card but there is no voice prompt?
Check whether there is a problem with the speaker, wire, or voice chip. If the problem remains, it may be that the voice potentiometer is not well adjusted and needs adjustment.
When a card is placed close to the Parking ticket dispenser reading head, a "beep" sound can be heard, but it display "invalid card".
Please check if the card held is invalid (not issued or not authorized), or if the card has been issued but its permissions have not been downloaded to the main board.
The license plate recognition equipment has been installed, but it does not recognize the vehicle entering the recognition area, nor broadcast voice.
Check the type of display screen chosen and the serial port configuration information (which should be 115200). If the issue remains unresolved after replacement, please check the RS485 connection and reconnect it to try again.
How to adjust the level of PB4000 pole?
Please adjust the springs inside the chassis.
What is the procedure if the key for the PLock1 is lost?
Please purchase a replacement lock cylinder and have it installed by a professional locksmith.
Why is the UHF reader recognition distance too short?
1. Check whether it is powered by an independent 12V power supply.
2. Contact our technical support for setup tools and guidance documents.
How can the LPRC300 be used offline? When trying to import files directly to the SD card, it failed.
Export the data first for local testing, update the data based on the exported Excel table, and then import it successfully. If it fails, check whether there is a problem with the data format.
Do you provide an SDK for the LPRC300 to develop and integrate with third-party software?
Yes, we have the corresponding SDK. Please contact our sales team.
Why can't the LPRC300 connect to ZKBio CVSecurity software?
When the device and software are on different network segments, you need to manually add the camera and change the port to 443.
Why does the connection between the TBM series Ticket Box and ZKBio CVSecurity software using the BEST protocol fail?
After TBM series settings are complete, manually restart the device for the settings to take effect.
Why can't LPR devices recognize license plates?
Please check if the settings are configured correctly. Then check whether the authorization file for the LPR module exists or is missing. If missing, please contact our technical support.
What Wiegand format does the U1000 support?
The U1000 supports WG26 and WG34 formats.
Why does the CMP200 gate not operate when the lift-off button on the remote control is pressed, but it operates when the handwheel is pushed a little?
It may be that the magnet adjustment of the Hall limit plate is not in place. Re-adjust the magnet position on the limit plate.
The ProBG3000 gate self-test is successful, but the remote control or the motherboard switch signal cannot control the gate to go up and down. Why?
Unplug the terminal of the remote control receiver and re-match the remote control. Observe the motherboard when using the remote control to see if the signal light illuminates. The power supply may be unstable. Set the DIP switch of the switching power supply to the AC position.
The landing lever of the BG300 is not fully in place after the machine has been operated with swapped left and right settings. What should be checked?
Please check if the spring strength and the gate lever are balanced at 45 degrees.
Check whether the movement polarity parameters are set correctly.
Adjust the horizontal L-6 and vertical L-9 parameters on the main board.
Loosen the screws of the rocker arm and re-adjust the spindle to reach the horizontal state.
Once the BG1000 gate is fully open, pressing the close button causes the gate to close at a slow speed. How can this be adjusted?
Depending on the length of the gate lever, adjust the closing parameter L-2 on the main board so that the speed reaches the appropriate value. After restarting the gate, press the main board's lever keys in sequence to let the gate learn one stroke.
Why BG2000 remote match not success?
It is difficult from mainboard setting, please use ZKBarrier APP from app setting, connect to app, from setting -remote control management, delete and add.
How to realize normally open when power outage by using PB4130?
The PB4130 does not support this function. Please change to another model or open the barrier manually during a power outage.
Why is the LPR300 web page very dark?
LPR has automatic and daytime two modes, set the daytime mode, in the daytime hours will not light up, after this time period, the page will become dark, LED lights will also be turned on.
The ProBG3000 is no work properly, and the motor beeps. It does not open and close or otherwise act when restarted, we already calibrated to 45 degrees and equipped with a safety input and the normally closed function is switched off.
The first dial code should be set to off, if it is set to on, the signal of rise and fall should also be normally closed, this switch is to control the input, usually the signal of rise and fall of the rod is normally open, set it and restart the machine.
Why does the VR10 keep showing a green light?
The device may detect an obstacle and then turn on the green light; it may also be a power supply problem. If the voltage is insufficient, an external adapter is required.
After the LPRS1000 recognizes a license plate, the voice prompt "welwelwelcom" is not continuous. The LPRS1000 is connected to ZKBio CVSecurity Ver6.6.3 software. Why does this happen?
1. The continuous capture mode needs to be turned off.
2. Adjust the continuous trigger interval(s) for the same license plate to 255.
Why does the UHF10 paired with UHF tags have poor reading performance, failing to recognize tags on vehicles?
This may be due to incorrect UHF tag usage or the need for adjustment of the UHF reader's angle.
1. Confirm the installation position of the tags and recommend corresponding tags based on the installation location.
2. Verify the installation angle of the UHF device. Generally, the installation height should be 2 to 2.5 meters above ground, and the device angle should be between 60° and 75° for optimal performance.
3. Use the UHF Demo to adjust the RF gain power of the UHF device, increasing it as much as possible.
After the ProBG turnstile opens, it cannot close. What could be the cause?
Troubleshooting revealed that the issue occurs only when connected to the CarID camera; when only the loop and switch controls are connected, it works normally. Please set the CarID's alarm output to "normally closed".
How should the BGM1000 barrier be wired?
Connect the radar to IN1 and GEN. Connect the barrier to the camera using IN2 and GEN. For the controller inside the BGM1000 barrier, connect the wires (IN2 and GEN) to the two OPEN terminals.
How should the BGM545L-F be debugged after replacing the main board?
Before powering on the replacement main board, the spring balance needs to be adjusted so that the barrier arm stays in place at a 45-degree angle, preventing the motor current from flowing back to the main board when it rotates. After adjustment, power on the device and observe whether LED1 flashes during operation. No flashing indicates stable operation. If it flashes, fine-tune the parameters or the spring again. The debugging requirements for dual-arm barriers are relatively high.
After the BG530 motherboard is powered on, it remains in the learning state. Once the learning process is completed, it suddenly jumps back to the "Start Learning" menu. What is the cause?
Set L-D according to the direction of the spring: set the left side to 3 and the right side to 0. After restarting the machine, the motherboard will perform the learning process again. Once the learning is completed, the barrier arm can be controlled to rise and lower.
Why can't the LPRC300 connect to the ZKBio CVSecurity software on the cloud server?
Enable the BEST protocol in the software menu and open port 8088 in the network firewall to search for and add the device.
Why does the UHF10 Pro reader automatically detect?
Please connect the UHF10 Pro to the tool via USB, and modify the "work mode" from "auto detect" to "trigger mode". During testing, a loop detector is required. You can short the purple cable with GND to imitate a loop.
The TBM01 is connected to the vehicle barrier. After ticket retrieval, the barrier sometimes opens and sometimes does not. How can this be resolved?
1. Use a separate wire to short-circuit the barrier's motherboard to send an opening signal, and check whether the barrier opens normally every time.
2. When the ticket is issued, use the multimeter's continuity test mode to measure NO1 and COM1 of the TBM01, and check whether it beeps each time. If it beeps every time, it indicates that the ticket dispenser is functioning properly; otherwise, there may be an issue.
3. Check whether the two signal wires between the ticket dispenser and the vehicle barrier are loose or damaged.
Why is the LPRS1000 inaccurate in recognizing license plate numbers?
Please contact our technical support for further inspection.
Why does the VR10 Pro not automatically lower the barrier when a vehicle passes by?
Download the app and adjust it according to the user manual.
Why is the TBM01 unable to print an admission ticket?
1. Check if the loop detector is installed correctly and connected to the correct port.
2. Check if the printer has paper.
3. Check if the printer is powered on.
4. If the above solutions do not resolve the issue, please contact our technical support.
The InBio260 controller is connected to two UHF10 Pro readers and two vehicle barriers. When UHF2 is connected to the reader2 terminal of the controller to open barrier2, barrier1 opens instead. How can this issue be troubleshooted?
The UHF10 Pro is connected to the controller via Wiegand wiring. First, check whether the reader interface connections on the controller are in the wrong order. If UHF2 is intended to control barrier2, it needs to be connected to the reader3 interface on the InBio260 controller. The reader1 and reader2 interfaces are both designated for UHF1 by default.
Why does the LPRS1000 gate not open automatically after identifying a fixed vehicle?
Please check if the fixed vehicle gate access setting in the access lane is set to automatic gate opening.
After a power outage and restart of the BGM400, the barrier arm stops at an open angle, and the main board reports an error. What is the issue?
During the barrier's self-check, the barrier arm is blocked by the eaves when opening, preventing it from fully opening. Even if the opening and closing angles of the barrier arm are set on the main board, the barrier still needs to go through the full travel during the self-check. Readjust the position of the barrier so that the arm is not blocked by the eaves.
Can the camera's infrared light be turned off manually?
Yes, you can manually turn off the infrared light by accessing the camera's web interface. Go to Parameters > Video Parameters, find the Light Board Control in the lower right corner, set it to "Off," and click "Save." A prompt will then indicate that the infrared light has been turned off after a successful save.
How to close boot wizard?
Enter menu "System Management > System Parameters > Other Configuration", deselect the "Launch Boot Wizard" option.
What’s the format of the video backup file?
The format of video backup file is AVI.
Why can’t find video record?
If can not find video record, check the HDD status first, then check the devices time(default year 1970) and adjust the time, then continue to record. Finally configure the video record plan.
How to reset IPC's password?
Please get the screenshot of password reset, and contact technical support.
How to add IPC to NVR in ZKBio CVSecurity software?
First search the IPC in Smart Video Surveillance > Device Management > Device > Grouping Device, and then input the user name andpassword, click "Add Device".
How to add NVR in ZKBio CVSecurity software?
First search the NVR in Smart Video Surveillance > Device Management > Device > Device, and then input the user name and user password, click "Add Device".
How to reset AntarVis 2.0 to default password?
1. On the login page, click "Forgot Password"
2. A string of characters was generated
3. Copy these character to our technical support
4. From the installation path D:AntarVis 2.0, the file cms.db was located and also sent to technical support
5. A new cms.db file was provided by technical support
6. The existing cms.db file was replaced with the new one
7. Upon logging in again, the default credentials is Username: admin, Password: 123456
Where are the files saved by the web page for IPC capture and video recording?
From the web page to accesses the IPC and go to the parameter - Local Settings, where you can confirm the file save path. If you need to modify the path, you can click the back view, and select the corresponding path and confirm, then click Save below.
How to switch IPC system format P and N?
From web page to access IPC, go to parameter - device information, select "System Format", switch and select "save". Then the device restarts, and the device standard switching is completed after the restart is completed.
What is the default IP Address / Username / Password of IPC?
IP address: 192.168.1.86
Username: admin
Password: 123456
Note: when restoring factory settings, you can choose to set the IP address as the default IP.
Can ZKTeco NVR be compatible with other manufacturers’ IPC?
The NVR can compatible with IPC of which supports ONVIF protocol.
Dose the NVR support ONVIF protocol?
Yes, NVR support ONVIF protocol, and the default port of ONVIF is 8082.
What video output interface does the NVR support?
The NVR support HDMI and VGA video output interface.
What’s the default IP / Username / Password of NVR?
IP Address: 192.168.1.88
Username: admin
Password: 123456
How to connect to ZKIVA-EDGE T1 box to ZKBio CVSecurity and set up cross-line detection?
The software first needs to have license points for the intelligent analysis module. Then set the T1 box, and finally set the cross-line detection in the camera Settings and software Settings. In addition, the video plug-in of the software must be consistent with the software version.
Why did the ZKIVA-EDGE T1 connect to the camera but fail to push events to ZKBio CVSecurity software?
Please troubleshoot problems from three aspects: software, firmware and network. If the network environment is OK, the software already the latest version.
It may be that the firmware version of the ZKIVA-EDGE T1 is too low. Please contact ourtechnical support for further support.
How to use ZKIVA-EDGE T1?
You can make some configurations and add channels in webserver.
The following is the default login method
IP Address:192.168.1.200
Username: hxgk
Password: hxgk1234
Why did the N2 experience noticeable lag when playing 4K videos?
N2 cannot support 4K and needs to adjust the video resolution to 1080P@25fps.
How to deal with the lack of target counting and object detection functions in the web interface of the GT-855P31C-S8-MI-S-HL?
Please contact our technical support for firmware upgrade.
What is the difference between ZD22-2K and ZD22-2K-A?
The ZD22-2K is a monitor screen, while the ZD22-2K-A is an office screen. Both come with interfaces such as VGA and HDMI, but they are designed for different usage scenarios.
The monitor screen is intended for long-term stable display. It features high brightness and sharpness, but prolonged use may cause eye strain.
The office screen, on the other hand, is built to meet office needs, offering better color reproduction and eye protection.
Why did the firmware upgrade for the BL-852Q38A-LP camera fail?
The upgrade proceeded normally after switching to Internet Explorer. The issue was related to browser compatibility with the old firmware, so switching browsers resolved the problem.
How to set the auto-switching of the status key on the F22?
State key check in/out automatically.
1. menu:Personalize~punch state options~punch state mode~auto mode
2. menu:Personalize~shortcut key mappings~F(1.2.3...)~set switch time
When enrolling fingerprint in device, device display a red 'X' on screen, and prompts: Failed! pls try again, the fingerprint can not be registered successfully.
Please go to device fingerprint auto test menu,
1. If fingerprint auto test fails, replace the fingerprint sensor with a new one.
2. If fingerprint auto test works normally, backup the data in device first, and then delete all data and register the fingerprint for a try.
3. If the problem remains, please contact our technical support and share the device's SN and MAC Address which you can get directly from devce menu. We will help to solve the problem.
How to calibrate the camera on the MB160 device?
Calibrate the camera (No Touch Screen) product:
1. the device menu: Automatic Test → Face Test
2. Press the "8" key once, then press the "9" key once to enter calibration mode.
3. After entering the calibration mode, the face detection box is displayed in red. Calibration is successful.After that, it automatically switches to a black and white face image, and the face detection box is displayed in green.
4. Exit the process.
When G4 Pro selects the verification mode as 'card only ', after swiping the card for verification, the device prompts the user to look at the camera for re verification.
Please go to device menu-system setting-Detection management-Enable mask detection to disable the mask detection function.
After Atlas-460 rebooted, the Webserver date reverted to 2000 year; the time returned to normal after reconnecting to the internet.
Please replace the button battery at the back of the device.
The SpeedFace-V3L device is new, and it restarts after detecting a face. The problem occurs even during automatic camera detection.
It is recommended to replace the motherboard for testing, as this is likely a motherboard malfunction. And also recommended to request assistance from our technical support engineers.
uFace302 device keeps restarting, can not start up normally.
1. If the device can start up to the main interface, and then restart again, please try to access the auto test to test for the fingerprint and camera, so we could judge whether it is the fingerprint reader or camera problem.
2. If the device restart speed is too soon to operate the auto test, please have a check at the fingerprint connection cable or camera cable if loose or demage.
3. Check if the camera or fingerprint reader is demage and change a new one for a try.
4. If replace the camera or fingerprint reader can not solve the problem, may check for the coreboard or contact our techinical support for a further check.
Uface device forget administrator, device time is not correct, do not know device IP, how to do?
Could use the USB drive to get the debug log to find the IP address, please follow below instruction:
1. create a folder named ZKUdisk in an empty USB drive root path;
2. plug in the USB drive to device USB slot;
3. power OFF the device, do not remove USB flash in device;
4. power ON device;
5. after main screen menu show, wait for 1-5 minutes;
6. remove USB drive, then check the ZKUdisk zipped file
check devs log to search for device IP.
After you get the device IP address, connect the device to software, and clear the device admin privilege.
How to fix device Connection issues to ZKBio CVSecurity Software?
If your access control device cannot connect to ZKBio CVSecurity software, follow the steps below to diagnose and resolve the problem.
1.Check Basic Network Connectivity
1) If device and the server are on the same local network.
① Ensure the device and the server (PC running ZKBio CVSecurity) are on the same network and can communicate.
② Ping test: From the server PC, open Command Prompt and run ping <device_ip_address>. If ping fails, check the physical connection, IP settings, and network firewalls.
2) if device and the server are not on the same network, eployed on the public network—you must ensure that the device can access the external network. Please check the IP address, gateway, DNS, and other related settings.
2) Temporarily disable Windows Firewall and any antivirus software on the server PC. If the connection works after disabling them, add exceptions for ZKBio CVSecurity.
2. Check Device Configuration
Access the device menu and confirm the following settings:
1)IP Address:
Go to Main Menu - COMM - Ethernet and ensure the device has a valid IP address, gateway, DNS, etc.
2)Cloud Server Settings (ADMS):
Go to Main Menu - COMM - Cloud Server Setting (or ADMS Setting) and check:
① Server Address: Must match the server PC's IP address.
② Server Port: Confirm the port used by your software (default is 8088).
3)Protocol:
Go to Main Menu - COMM - PC Connection and check:
Make sure HTTP or HTTPS is selected according to your software configuration. If the software uses HTTP, ensure HTTPS is disabled on the device; if the software uses HTTPS, enable HTTPS on the device.
4)Device Type / Push Mode:
Go to Main Menu - System - Device Type Settings,
Communication protocol: Push Protocol;
Device Type: A&C Push (or Acc Push).
Note: The device must be in Access Control push mode to be recognized by the ZKBio CVSecurity Access Control module. If you intend to use it for attendance, set the appropriate push type accordingly.
3. Add the Device in ZKBio CVSecurity Software
1) Open the ZKBio CVSecurity software and navigate to the Access Device module (or the relevant module matching your device’s push type).
2) Click the Search button. After scanning, the device should appear in the list.
3) Select the device and click Add. If prompted, confirm the settings.
4) After adding, refresh the device list. The device status should become online.
If the device is not found during search:
1) Try using the “Add Manually” option by entering the device IP and credentials.
2) Clear your browser cache or try a different browser (if using web client).
3) Ensure the device is not already added to another software or server.
4. Advanced Troubleshooting
If the above steps fail, check the following:
1)Firewall on routers or intranet: Ensure port 8088 (or your custom port) is open for communication between the device and server.
2)Software version compatibility: Confirm that your device firmware is compatible with the ZKBio CVSecurity version. You may need to upgrade the device firmware or software.
If none of the above resolves the issue, contact our technical support and provide: the software version, device firmware version, and push version, a brief description of steps already attempted. This information helps technical support diagnose the issue.
The F22 device does not have an HTTPS option.
Please contact ZKTeco technical support for firmware upgrade.
To the near-infrared or visible light facial recognition devicee, such as uFace302 or SpeedFace V5l, cannot register / cannot recognize faces, camera is not working. Or after replaced the camera, device cannot recognize faces.
1. Go to device menu - Settings - test - camera test to detect faces. If there is no image, the camera is damaged or the wire connection has problem. Check the connection or replace a same version camera module for a try.
2. If in auto test, the camera can detect faces, but only show color images oronly show black & white images, please contact the our technical support for a further check.
3. If this problem happened after change the camera, please collect the old camera version and the new camera version, device serial number and firmware version, then contact our techinical support for a further check.
How doese the SenseFace 4A upgrade language?
Please send the device serial number, firmware version and which kind of language you want to upgrade to our Technical support for further comfirmation.
The fingerprint recognition function of the fingerprint device does not work, when pressing the fingerprint, there is no response at all, it did not prompt please try again, nor did it prompt success.
1. Clean the fingerprint scanner. Ensure fingers are clean and dry then try again.
2. Enter the device menu>Settings>test>fingerprint test and press your fingerprint to detect whether there is an image. If there is no image, check the fingerprint sensor wiring connection lose or not, or maybe the fingerprint sensor is damaged, please try to replace with a good working fingerprint sensor from the same modle for a try.
3. If there are fingerprint images, please contact our technical support and share the device's SN and MAC Address, we will help to debug and solve the problem.
To the visible light devices (such as SpeedFace-V5L) with mask detection function, please have a check whether you have turned on the mask recognition detection, if so, please trun it off and try again.
How can SpeedFace-V5L device upgrade custom logo?
Please contact our technical support for further confirmation.
What phenomena might occur if lack of power supply?
1) ICR switches frequently.
2) The camera’s image looks dark.
3) Some ripples appear in the image.
4) The camera might reboot frequently.
Why is the camera’s image unclear?
1) Unmatched lens mount. There are two types of lens mount for box
cameras,respectively are CS mount and C mount, the lens and camera must
be matched with the same type.
2) Use Focus in / focus out to control the Clarity.
3) Check whether the lens or housing gets dirty.
4) In case of strong light condition, please select electronic iris as the lens type.
What is SMART Face Detection?
Face Detection: Face Detection function is fulfilled by the camera. The face features such as eyes and mouth would be recognized. The detection highly demands the size of face shown in the image and the angle to the lens. We recommend users have the camera installed close to the desired detection region and make sure people face the camera directly. Notice: Face Detection is different from Face Recognition. In Face Detection, the detection of faces in the whole image would trigger the alarm and notify surveillance center. The regions of detected faces would not be captured. The Face Recognition Camera is able to capture face images and upload to server for face comparison.
If I forgot the password of ZKTeco IP camera, how can I login in the Client software?
Why our DVR/NVR cannot find the HDDs?
Please install the HDD properly, no gap with the interface. Please install recommended HDD, eg. Seagate, WD, TOSHIBA, SANSUNG, HITACHI (generally capacity: 1T, 2T, 4T, 6T, 8T).
What is Main stream / Sub stream?
The main stream with high resolution and full frame rate can be used for main monitoring and recording. The sub stream with lower resolution can be used for mobile monitoring. Some devices support third stream which offers more flexible choices.
What are Stream and Bitrate?
After the video is compressed, a stream is generated. Bitrate (bps): quantity of bit stream per second. Bitrate type: Constant Bitrate (CBR), Variable Bitrate (VBR). Stream type: video, audio, video & audio complex stream.
What is DVR / NVR?
DVR/NVR is a management device which realizes the function of centralized storage, local live view, search, playback and other functions. The main difference between DVR and NVR is the function of encoding. DVR is an encoding unit, but NVR does not have this feature.
What is H.264+?
H.264+ technology is a kind of intelligent algorithm developed by Hikvision. It is a remarkable encoding technology which focuses on the features of the surveillance video and is optimized based on the H.264/AVC. H.264+ lowers the bitrate of the surveillance video greatly so as to save the system cost.
What is ONVIF?
ONVIF is committed to providing and promoting open interfaces to the security industry for effective interoperability of IP-based physical security products.
What is Resolution?
Resolution is usually measured by the number of horizontal and vertical pixels. It can be expressed as number of horizontal point * number of vertical pixels. In a fixed plane, the higher resolution could provide better image.
What is PoE Power Supply?
Only the network camera has POE. 1,2,3,6 are the data wire and 4,5,7,8 are idle. Two methods can be applied. With 8-core wire, one method is using 1-4 cores for both power supply and data transmission. Another method to use 5-8 cores for power supply while the rest for data transmission.
What does 4K mean?
The name "4K resolution" refers to a horizontal resolution of approximately 4,000 pixels. It has been developed into a variety of standards. The DCI 4K resolution standard (4096 * 2160 pixels) is widely respected by the film and video production industry. Besides, UHDTV standard (3840 * 2160 pixels) is also popular which has twice the horizontal and vertical resolution of 1080p (as shown in the figure below).

If I forgot the password of DVR / NVR, how can we login in DVR / NVR.
Please send us the snapshot of DVR/NVR screen with clear date and time (as below),we will give you a super password to login in the DVR/NVR.

ZMM100 Mifare device, if enroll card both in user manage menu, and Card management menu.it will verify failed.
After test we found, that if you just enroll from user mng, or card mng menu, it can verify succeed, If enroll from user management, then enroll again from card management, it will ask copy data to card or not, if we choose no, it could not verify succeed on device. But if we choose yes, we could still verify succeed. If meet this issue, just tell customer to enroll from one of the menu.
customer enroll 3297 fingerprint in Alg 9.0,every time when they verify fingerprint, the device will ask for user ID.
In Alg 9.0, if extend 3000 FP, the device will force to 1:1 mode, In this case,we would like to suggest customer to use Alg 10.0.
Can we set whether the work code must be entered when the employee verifies? And how to transfer the work codes from one device to another?
Please go as follow to choose the work code options Menu->Work Code->Work Code Option->Work Code Required ( turn it “On”.) How to transfer the work codes from one device to another? Please go as follow: 1)Download the work codes from device A: USB Manage->Download->Work Code. Upload the work codes from device A to device B: USB Manage->Upload->Upload work code.
If I have used the usb client function on the device, then can I use the wifi function?
These two functions are not compatible with each other. Only when the usb client function is closed, then the wifi function can be used.
If I have open the GPRS function of the device, then can I use the print function
These two functions are not compatible with each other. Once the GPRS function is used, the print function can not be used.
Can we set a certain time to download the logs, and then delete the logs in the device automatically instead of deleting manually?
Please firstly go as follow in the ZKtime.net software: System->Plan Task. Then please go as follow in the ZKtime.net software: System->General.
How to connect the device with the Zktime.net software?
Firstly, please go as follow: menu->Comm->Ethernet(Set the “IP Address”, “Subnet Mask”. “Gateway”. And the TCP COMM port should be 4370). Secondly, please go as follow: menu->PC Connection->Comm Key to be “0”. Thirdly, please go to the zktime.net software, and set as follow: (Let the port to be “4370”, And the pwd to be blank)
How to import the user information from the device to the software via U disk?
Firstly, please download the user information with the U disk. Then please go as follow in the Zktime.net software: Attendance->Import / Export->Import Employees.
If the device needs to change its attendance status automatically, how to achieve that?
Please go as following: menu->Personalize->Shortcut key mappings->Set switch time. Then the status will automatically change when it reaches the time you set.
How to enter ADMS with URL mode? Where to input the port when using the URL mode?
Please go as following to set: menu->COMM->ADMS. And pls turn the “enable domain name” to be “on”, and about the port, pls directly input it together on the domain name such as “abc:8081” in the server address.
Can I take a photo of the user if his fails to verify for continuously three times?
Yes, Please go as the follow path to do some settings: menu->System->Attendance->Camera mode->Save on failed verification.
How to save the illegal verification record.
Please go to the follow path to turn on this function: menu->System->Attendance->Save Illegal Verification Record (Turn it on).Then the device will keep the record though it is illegal.
How to change the advertising pictures of the device?
Create a new folder named "advertise" in the root directory of U disk and place advertising images into the folder. A maximum of 20 images can be stored and the size of each image cannot exceed 30 KB. There are no restrictions on the image’s name and type.
If the device connects with a printer, how to set the printer function on the device? Can the paper be cut automatically when it comes out?
Please go as the follow path: menu->Print->Printer Options->Print (On)->paper cut (If you need it, turn it as“on”) , Then go as below: menu->Print->Data Field Setup (choose to turn on those functions you need.) Thirdly, go to Menu-->Comm.-->RS232/485 and select baud rate. Here is the connection between the device and the printer.
How to change the wallpapers of the device?
Upload the jpg documents with “1~10.jpg” as initial letters of document names stored in a U disk to the terminal. After the upload, these pictures can be displayed on the interface of the terminal. Create a new directory named "wallpaper" in the root directory of U disk and place wallpapers into the directory. A maximum of 20 wallpapers can be stored and the size of each wall paper cannot exceed 30 KB. Pls go as the follow path to upload: menu->USB Manager->Upload->Wallpaper.
There is a triangle together with a red “!” on the top of the main screen, how to cancel it?
It is a signal of the Alarm when the device is getting down from the wall. When the device is installed on the wall normally, this signal will disappear automatically.
How to use wifi with new firmware device?
Pls go as follow: menu->COMM->Wireless Network




Can we set the valid date for the employee?
Please go as follow: menu->User Mng->New User->User Expiration Rule->Expired Date->Start Date->End Date. If the user verifies outside the date, the device would say “invalid user”.

Can FR1200 support Ver9.0? Can FR1200 be connected with C3?
NO, FR1200 can only support Ver10.0; FR1200 can not be connected with C3, because C3 does not support fingerprint.screen, how to cancel it?
How to get the license after reinstall ZKTimeNet 3.0 on another computer
After the computer is replaced ,the licnese have to sent to the licnese issuer for reset. The default is that each licnese of customer have a chance to replace license for free.
What the customer needs to do:
1-send the old Activation file to yo technical support or sales.
2-your company name and country.
The method of restoring database when reinstalling net3.0 is sent to you as an attachment. Please check it.
Method of restoring database when reinstalling net3.0.pdf
why the device shows GPRS online BUT failed to connect to BS software
Check the Sim Card. Some card requires to open data first even it shows online and shows the data transfer, make sure that you could use the SIM card login FaceBook or anyother web. After , insert the SIM card back to device
Uface800 auto restart
Check fingerprint reader and camera. Replace damage fingerprint reader or camera. Pay attention to replacing the correct type of fingerprint reader or camera.
The mysql database was selected when installing BioTime 8.0. An error occurred: unknown error.
Ignore errors,and after the successful installation,reconfigure in the console.

Access3.5 sets the authentication mode, VF300&MB360 does not change
The VF300 & MB360 products are time and attendance terminals with simple access control.
The operation of modifying the verification mode on the Access 3.5 software is for the access control.Therefore, the software is set up and the device has not changed.
Only devices with advanced access control can synchronize the authentication settings on Access 3.5 to the device.
Device can not connect ZKBio TIme
phenomenon :
In theZKBio Time, the device state is online.,but cannot show device model and the version information,and the device name is still auto add.
Solution:
Just click the auto add, and add an new name to device,then the device information will be appears completely.
Big Device capcity
For a big device capcity. You can make a mark with the sales first before you make the new order.
And if you want to upgrade the capcity in your hand , please contact with the supplier to know whether we can do it or not.
Login the webserver3.0 of device
the webserver address is your device ip address.
If the device doesn't have admin, the login accout and the password of the web 3.0 are administrator and 123456.
If your device contains admin user, the login accout and the password are the admin user's ID and password.
Cloud Server Setting (ADMS) shows Disabled.
Contact technical support to set device parameter:ServerType=0
What is dry mode and wet mode ?
The control panel supports “dry mode” and “wet mode” by using the jumper. For “wet mode”, short 2-3 and 4-5 terminals. The control panel and the lock use the separate power supply. One is connected with +12V and GND of POWER interface (for the control panel), the other is connected with V+ and V- of LOCK interface (for the lock). The factory default jumping is set as dry mode.
which reader of the inbio controls which door?
About C3-200, the reader1 and reader3 are the in of lock 1 and lock 2; reader 2 and reader 4 are the out of lock 1 and lock 2. About C3-400, all of the readers are for the in of the lock. When C3-400 changes to two-door two-way, the reader 1 is for the in of lock 1, the reader 2 is for the out of lock 2; the reader 3 is for the in of lock 2, the reader 4 is for the out of lock 2. If for inbio, the odd number is for in of the lock, the even number is for out of the lock.
Inbio+FR1200,can FR1200 be used to register users?
FR1200 can not be used to register fingerprint, it can only be used for verification. Fingerprint sensor such as ZK4000,ZK4500 can be used to register users. The ZK4000 can be used only in 32 digits system; but ZK4500 can be used both in 32 digits and 64 digits.
How to cancel the event records in the inbio?
The event records can not be cleared; when it reaches 100,000, it will overlap the before ones.
The number 7 is used to restore to the factory setting, which kind of data will be initialed? Including the parameters setting?
If you forget the device IP or the device can not work normally, You can use the number 7 terminal to restore inbio460 to factory Setting , the configuration include device IP , communication password ,gateway ,subnet mask. The device IP will be 192.168.1.201,the communication password will be blank. And the parameters setting will not be changed, will stay at the device.
How to reset the device to the factory setting?
The number7 digit is off by default. When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted.
Inbio260 can only support one FR1200? How to set the 485 address of FR1200?
Inbio260 can at most support four FR1200, two as in, two as out. There are six DIP terminals , 1-4 is for RS485 address , 5 is reserved , 6 is for extending the length of RS485. Set the odd number is for enter reader, and the even number is for exit reader (for example , two readers for one door- the rs485 address 1 is for enter door, rs485 address 2 is for out door) And both 1 and 2 should be translate into the binary digits.
ZKAccess3.5 startup failed
problem:I receive an error message "root element missing" when i try to launch software
sloution:First ,please Go to the software installation directory, and find ‘AppSite.Xml’.(Please backup this file before doing the following.)

Then open it with Notepad.
Check the value of this statement,for example,the value of mine is ‘’en’’ ,and in the second red box you can see the vaule of ‘’en’’ is ‘’English’’.
Please try to modify the value to ‘’en’’or’’chs’’,then save the file and restart the software ZKAccess3.5 to see if it can run successfully
If you have any problem please contect me.Have a good day.

access the access control device directly without the use of ZKTeco software, using c#
This is the download link for the SDK:
https://www.zkteco.com/en/search?keywords=standalone%20SDK
TF1700 doesn't push oplog
The reason is wrong timestamp, delete / data / oplog.dat and restart device,run demo,it will start to push oplog.
Attendance module disappears after Access3.5 activates public license
The attendance module of the new version of ZKAccess3.5 is chargeable and requires a license. The public license does not include this feature.
ZKBioSecurity and Set Valid Time of 7B
When we want to use 7B's Set Valid Time, we need to enter the device's menu, open the setting (Expiration Rule end setting).
The menu path is:
Menu->System Setting ->Access control record settings->Expiration Rule end setting :

When using ZKBio Access and license has been activated,but get the error: "The points in the system mismatch with the licence points"
Please click on cancel and active again.

Defective touching ( Projected Capacitive touchscreen)
1. The wire connecting touchscreen with main board is defective, the
control card of touchscreen or the internal USB is defective, or the
Operation System is broken. Check all possible reasons above one by one,
then change accordingly.
2. Change the control card, or change touch screen
3. Change touchscreen
Change touchscreen
Defective touching ( Resistive touchscreen )
1. No touching drive, the wire connecting touchscreen with main board is
defective, the control card of touchscreen or the internal USB is
defective, or the touchscreen itself is defective. Check all possible
reasons above one by one, then change accordingly.
2. Try the operation of 9 or 25 points linearity correction, if still
cannot work, probably the control card or touchscreen is defective, need
to change touchscreen
3. Try the operation of 9 or 25 points linearity correction, if still
cannot work normally, probably the control card or touchscreen is
defective, need to change touchscreen
Change touchscreen
Defective display
1. Change LCD
2. Screen line is broken, or BIOS setting is incorrect, or change LCD
3. Change LCD
LCD or LCD backlight is defective, change LCD.
Able to boot and fail to access the operating system
1. Reinstall operation system, ensure all important data is kept safely.
2. Starting up in security mode, antivirus checking, or reinstall operation system.
3. Pull out hard disk and insert again
4. Reboot operating system
Change new hard disk
Unable to boot and power indicator is on
1. Change Main board Pull RAM bank out and insert again, or change RAM bank
Unable to boot and power indicator light is not on
1.Checking power outlet 2.Change adapter 3.Check electric line from main board or change main board Change switch or the cable
If the fingerprint reader does not work, how do we know where the problem is?
1) Confirm the fingerprint reader firmware version, which can be read using a small program.
2) Confirm the software used and its ZKFinger SDK version.
3) Is the released ZKFingerSDK 5.3Lite demo version normal?
4) Provide test steps, video or error screenshots as much as possible.
The registration speed of the SLK20R connected to the ZKAccess 3.5 software is normal, but the registration is slow when ZKBiosecurity3.0 and ZKTime web2.0 are connected.
Please update the latest ISSonline SDK test. SLKID 1.4 or less and 1.4 or more are different. Old SDK Under 1.4 Firmware USB2.0 fetched original map at SDK layer probe speed acceptable Before 1.4~2.0, the firmware used USB1.1. If you continue to transfer the original image, the speed is very slow. After the SDK upgrade, the correction map is read. The data is much smaller than the original image and is not so slow.
The following exe can not run: C:\Necsis2\Liberaciones\NEC_FPExtract_X64_20180116\NEC_FPExtract_X64_20180116>sa mple.exe
The application has failed tostart, because its side-by-side configuration is in Use sxstrace to track issues: Sxstrace trace -logfile:trace.bin Then open the application, this time in the trace.bin root directory has been generated, so exit sxstrace, Run the following command again: sxstrace parse -logfile:trace.bin -outfile:trace.log You can see related information. The current check found is the C++ runtime library that has been installed by the customer
The source code in the python DEMO is handed and compiled with exceptions. Prompt missing files, such as ZKFPEngXControl_TLB.
You need to install the Biokey.ocx control in Delphi. After installing the ZKFinger SDK5.3 Lite driver, Biokey will be stored in the program directory, for example: C: Program Files FPSensor Biokey.
When integrating the SLK20R into an Android application, customers cannot find liblibzkfp.so for the ZKFPService class in the JAVA SDK.
Demo error: 'System.Runtime.InteropServices.COMException' occurred in System.Windows.Forms.dll Additional Information: Unregistered class (HRESULT exception: 0x80040154 (REGDB_E_CLASSNOTREG))
Unregistered class, confirming the client's operating system and the number of used SDK bits, suggesting that the client's debugging platform be changed from x64 to x86
The ZKFingerModuleSDK command MD_READ_USER can only obtain the number of templates when acquiring user data from the SLK20M. Cannot obtain the template number?
The ZKFingerModuleSDK command MD_ENROLL_TMP issued a fingerprint to SLK20M failed.
When the command issued a fingerprint, base64 format encoded fingerprint needs to be decoded
Does ZKFingerSDK provide fingerprint template conversion interface?
ZKFingerSDK is not provided, there is another conversion library that can provide conversion interface.However, only ZK10.0 fingerprint templates are currently supported for conversion to ISO/ANSI templates. ISO conversion to ZK fingerprints is not supported.
How big USER ID does the SLK20M support?
Our biometric identification SDK does not involve user IDs.Since a person has 10 fingerprints, we only have a finger index, which is a 32-bit unsigned integer, a pure number that does not exceed 9 in length. Our SDK only cares about the information he collects, then compares it and does not care about logical data.
Is it possible to convert our 10.0 fingerprint template into a picture (jpg, png, etc)?
Fingerprint template can't convert pictures. The binarization process of extracting fingerprint feature points from a picture and saving it as a fingerprint template is irreversible.We can get the original fingerprint image from the fingerprint reader through the SDK interface ZKFPM_Acquire Fingerprint Image. It does not support converting from a fingerprint template to a picture.
Fingerprint comparison always fails
1. Confirm whether the fingerprint template of the customer is correct
2. Confirm that the customer's own development process has judgments on
algorithm library initialization and fingerprint reader connection. The
algorithm library initialization may fail but the client still invokes
the comparison interface.
Connected fingerprint reader and not, the result is not the same
Due to the limitation of the algorithm, a fingerprint reader must be connected in order to initialize the algorithm library and the comparison interface can be invoked.
When installing the ZKBiolock on the win10 pro operating system, the software prompt database is incompatible with the operating system.
First install the SQL Server2012 database and then install the ZKBiolock, and configure the database in the software.

EU01 can't get card number from external wiegand reader
It shows "invalid card number" when you try to register card number for a new user. Need to close parity check of wiegand reader,set parameter ExtNeedParity to 0.
External alarm doesn't work on K30 PRO
Check if you have access control menu,you can have access control function or external alarm,only one of them. When you have access control function disabled,you will see the menu in system setting to switch internal/external alarm.
ZKBioSecurity3.0 trial information
For ZKBioSecurity3.0 , it offer 30 days for you to test , no need to get the license. you are free at the first 30days after installed . And if you don't think it is enough for you , you could check the demo link in our website to test more.
When using ZKBio Access and license has been activated,but get the error: "The points in the system mismatch with the licence points"
Please click on cancel and active again.